PERBANDINGAN METODE PENENTUAN KADAR KANAMISIN SULFAT dalam MATRIKS UDANG dengan KLT-BIOAUTOGRAFI KONTAK dan KLT-BIOAUTOGRAFI IMERSI AGAR

APRELITA NURELLI DWIANA, 051411133007 (2018) PERBANDINGAN METODE PENENTUAN KADAR KANAMISIN SULFAT dalam MATRIKS UDANG dengan KLT-BIOAUTOGRAFI KONTAK dan KLT-BIOAUTOGRAFI IMERSI AGAR. Skripsi thesis, Universitas Airlangga.

[img]
Preview
Text (Abstrak)
FF.KF. 47- 18 Dwi p Abstrak.pdf

Download (149kB) | Preview
[img] Text (Fulltext)
FF.KF. 47- 18 Dwi p.pdf
Restricted to Registered users only until 13 December 2021.

Download (2MB) | Request a copy
Official URL: http://lib.unair.ac.id

Abstract

A simple thin-layer chromatographic (TLC) bioautography has been established for analysis of kanamycin sulphate in shrimp. The purpose of the study was to determining the better method was to for analysis of kanamycin sulphate analysis in shrimp between TLC-bioautography contact and TLC-bioautography agar-overlay. Kanamycin sulphate was separated from another component using silica gel 60 GF 254 and KH2PO4 10% as mobile phase. Eschericia coli ATCC 8739 was used as test antibacterial activity. Resolution factor (Rs) between kanamycin sulphate and streptomycin sulphate was 3,47 for TLC-bioautography contact and 3,85 for TLC-bioautography agar-overlay. TLC-bioautography contact detection limit of kanamycin sulphate was 70 ppm and quantitation limit was 231 ppm. TLC-bioautography agar-overlay detection limit of kanamycin sulphate was 70 ppm and quantitation limit was 231 ppm. TLC-bioautography contact response was to be linier at the range of kanamycin sulphate concentration between (100,1 – 200,02) ppm (y= 4,6398x-6,7705; r= 0,970; Vxo = 1,525%). TLC-bioautography agar-overlay response was to be linier at the range of kanamycin sulphate concentration between (100,10 – 200,02) ppm (y = 4.0641x-2.9968; r = 0,998; Vxo = 1,017%). Average recovery TLC-bioautography contact and agar-overlay were 100,47% and 100,73%, respectively. Thus based on result of validation we can conclude based specificity, LOD and LOQ, linearity, acuration and precision both of method were fulfill requirements validation parameters. However, this research also conclude that TLC-bioautography agar-overlay is better than TLC-bioautography agar-overlay for determination kanamycin sulphate in shrimp.

Item Type: Thesis (Skripsi)
Additional Information: KKB KK-2 FF.KF. 47- 18 Dwi p
Uncontrolled Keywords: TLC-bioautography, contact, agar-overlay, kamanycin sulphate, shrimp
Subjects: R Medicine > RS Pharmacy and materia medica > RS1-441 Pharmacy and materia medica
Divisions: 05. Fakultas Farmasi > Kimia Farmasi
Creators:
CreatorsNIM
APRELITA NURELLI DWIANA, 051411133007UNSPECIFIED
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorIsnaeni, Dr. Hj., MS., Apt.UNSPECIFIED
Thesis advisorFebri Annuryanti, S.Farm.,M.Sc.,Apt.UNSPECIFIED
Depositing User: Tatik Poedjijarti
Date Deposited: 13 Dec 2018 18:13
Last Modified: 13 Dec 2018 18:13
URI: http://repository.unair.ac.id/id/eprint/76745
Sosial Share:

Actions (login required)

View Item View Item