Ademas Prasasti Panji Pradana (2012) Penundaan Pengisian Bahan Cetak Polyether Terhadap Perubahan Dimensi Linier Model Kerja Gips Keras Tipe Iv (Eksperimental Laboratoris). Skripsi thesis, UNIVERSITAS AIRLANGGA.
Text (HALAMAN JUDUL)
1. HALAMAN JUDUL.pdf Download (614kB) |
|
Text (ABSTRAK)
2. ABSTRACT.pdf Download (531kB) |
|
Text (BAB 1)
3. BAB 1 PENDAHULUAN.pdf Download (516kB) |
|
Text (BAB 2)
4. BAB 2 TINJAUAN PUSTAKA.pdf Restricted to Registered users only until 4 January 2023. Download (593kB) | Request a copy |
|
Text (BAB 3)
5. BAB 3 KERANGKA KONSEPTUAL.pdf Restricted to Registered users only until 4 January 2023. Download (513kB) | Request a copy |
|
Text (BAB 4)
6. BAB 4 METODE PENELITIAN.pdf Restricted to Registered users only until 4 January 2023. Download (1MB) | Request a copy |
|
Text (BAB 5)
7. BAB 5 HASIL PENELITIAN DAN ANALISIS DATA.pdf Restricted to Registered users only until 4 January 2023. Download (602kB) | Request a copy |
|
Text (BAB 6)
8. BAB 6 PEMBAHASAN.pdf Restricted to Registered users only until 4 January 2023. Download (546kB) | Request a copy |
|
Text (BAB 7)
9. BAB 7 KESIMPULAN DAN SARAN.pdf Restricted to Registered users only until 4 January 2023. Download (503kB) | Request a copy |
|
Text (DAFTAR PUSTAKA)
10. DAFTAR PUSTAKA.pdf Download (510kB) |
|
Text (LAMPIRAN)
11. LAMPIRAN.pdf Restricted to Registered users only until 4 January 2023. Download (720kB) | Request a copy |
|
Text (EMBARGO)
12-020710056_ADEMAS PRASASTI PANJI PRADANA (Kesediaan Publikasi) - Ademas Prasasti.pdf Restricted to Registered users only Download (551kB) | Request a copy |
Abstract
Background: Dental impression is an important stage in the preparation of dental prostheses. Fixed bridge abutments impression needs high accuracy and good dimension stability. Delayed pouring of impression material could happened on limited factor of the dentist and assistant in sending the impression to dental laboratory. Impression material should not distort during the storage period. The distortion of the inter abutment linear dimension will disturb the path of insertion bridge. Purpose: to investigate the effect of delayed pouring polyether impression material on the linear dimensional change on die of the gypsum type IV. Material and Methods: polyether impression material was taken on stainless steel master model. The impression was poured by type IV gypsum after stored for 30 minutes, 1 day, 3 days, and 7 days. The impression was stored in a box at + 51% - 56% relative humidity and + 270 C room temperature. Type IV gypsum was poured to the impression placed on the vibrator, with the composition of 24 ml : 100 gr W/P ratio. Linear dimension was measured by a digital caliper. The data was analyzed by one-way Anova test (α = 0.05). Result: the means value of linear dimension on 30 minutes delayed pouring (control group) is 18.979 mm, 1 day delayed pouring (P1 group) is 18.983 mm, 3 days delayed pouring (P2 group) is 18.981 mm, 7 days delayed pouring (P3 group) is 18.978 mm. Conclusion: delayed pouring of polyether impression material in 1 day, 3 days, and 7 days do not show significant changes on inter-abutment linear dimension of type IV gypsum dies.
Item Type: | Thesis (Skripsi) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Additional Information: | KKA KK KG 09-20 Pra p | |||||||||
Uncontrolled Keywords: | Polyether, Type Iv Gypsum, Linear Dimension | |||||||||
Subjects: | R Medicine > RK Dentistry > RK1-715 Dentistry R Medicine > RK Dentistry > RK641-667 Prosthetic dentistry. Prosthodontics |
|||||||||
Divisions: | 02. Fakultas Kedokteran Gigi | |||||||||
Creators: |
|
|||||||||
Contributors: |
|
|||||||||
Depositing User: | prasetyo adi nugroho | |||||||||
Date Deposited: | 04 Jan 2021 04:28 | |||||||||
Last Modified: | 04 Jan 2021 04:28 | |||||||||
URI: | http://repository.unair.ac.id/id/eprint/102517 | |||||||||
Sosial Share: | ||||||||||
Actions (login required)
View Item |