I Ketut Alit Utamayasa, - and Mahrus A. Rahman, - and Taufiq Hidayat, - and Rendi Aji Prihaningtyas, - (2020) A Preliminary Study: Troponin T and Reg3β in Children with Left-to-Right Shunt Congenital Heart Disease with Heart Failure. Indian Journal of Public Health Research & Development, 11 (3). pp. 2431-2435. ISSN 0976-0245
Text (Artikel)
A Preliminary Study Troponin T and Reg3β in Children with Left-to-Right Shunt Congenital Heart Disease with Heart Failure.pdf Download (412kB) |
|
Text (Similarity)
A Preliminary Study Troponin T and Reg3β in Children with Left-to-Right Shunt Congenital Heart Disease with Heart Failure.pdf Download (1MB) |
|
Text (Peer Review)
A Preliminary.pdf Download (1MB) |
|
Text (Bukti Etik)
Surat Keterangan 6.pdf Download (340kB) |
|
Text (Peer Review)
13.pdf Download (638kB) |
|
Text (Bukti Korespondensi)
Bukti Korespondensi A Pre.pdf Download (396kB) |
|
Text (Karil)
13.pdf Download (62kB) |
Abstract
Background: Congenital heart disease (CHD) cause heart failure and myocardial injury. Troponin in the heart is a biomarker of myocardial injury in adults and children. Studies that examine troponin T and Reg3β in children with left-to-right shunt CHD with heart failure are still limited. Objective: This study aims to analyse the troponin T and Reg3β in children with left-to-right shunt CHD with heart failure compared to children without heart failure. Method: This study was a case control study of children with left-to-right shunt CHD with heart failure and children with left-to-right shunt CHD without heart failure performed with non-random sampling consecutive techniques at the Dr. Soetomo General Hospital, Surabaya in April–June 2019. The diagnosis of left-to-right shunt CHD was determined based on echocardiographic examination. All subjects with left-to-right shunt CHD were evaluated using the Paediatric Heart Failure Score. Troponin T examination was carried out using a one-dimensional electrophoresis technique, which is 12% sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Reg3β examination was carried out by the ELISA method. Data analysis was performed with an independent sample t test using the SPSS. Results: This study involved 11 children, consisting of 7 children with left-to-right shunt CHD with heart failure and 4 children with left-to-right shunt CHD without heart failure. Most children (72.7%) were female, 3 children (27.3%) were > 5 years old, 5 children (45.4%) were 5–10 years old and 3 children (27.3%) were > 10 years old. There was a significant increase in the Troponin T and Reg3β in children with left-to-right shunt CHD with heart failure as compared to children without heart failure. Conclusion: Troponin T and Reg3β can be used as biomarkers in children with left-to-right shunt CHD with heart failure.
Item Type: | Article | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Uncontrolled Keywords: | Congenital Heart Disease, Troponin T, Reg3β, Heart Failure | ||||||||||
Subjects: | R Medicine > R Medicine (General) R Medicine > RJ Pediatrics |
||||||||||
Divisions: | 01. Fakultas Kedokteran > Ilmu Kesehatan Anak (Sub Spesialis) | ||||||||||
Creators: |
|
||||||||||
Depositing User: | arys fk | ||||||||||
Date Deposited: | 09 Aug 2021 06:06 | ||||||||||
Last Modified: | 17 Jan 2023 08:41 | ||||||||||
URI: | http://repository.unair.ac.id/id/eprint/109019 | ||||||||||
Sosial Share: | |||||||||||
Actions (login required)
View Item |