Estimasi Dosis Efektif Pemeriksaan CT-Scan Kepala Non Kontras Pada CV A Dengan Menggunakan CT-Scan 128 Slice Terhadap Perubahan Scan Length di Unit Radiologi IGD RSUD DR. Soetomo Surabaya

Ayu Ismi Kartikasari, - and Yahya Febri Ningtyas, - and Rifka Sogiyana, - (2015) Estimasi Dosis Efektif Pemeriksaan CT-Scan Kepala Non Kontras Pada CV A Dengan Menggunakan CT-Scan 128 Slice Terhadap Perubahan Scan Length di Unit Radiologi IGD RSUD DR. Soetomo Surabaya. Tugas Akhir D3 thesis, UNIVERSITAS AIRLANGGA.

[img] Text (TUGAS AKHIR)
KK FV R 09-15 Kan e.pdf

Download (11MB)
Official URL: http://www.lib.unair.ac.id

Abstract

The background of this research is aCT-Scan Head ofNon-Contrast in Dr. Soetomo in theory examination conducted ranging from 1 em base -vertex. But in reality on the ground is still found workmanship CT scan head in the case of CV A that its scan area of more than 1 em. This enables the effective dose received by patients, especially with the latest technology advances that the CT scan that can display the estimated effective dose received by patients increased. In the world of radiological safety of the patient should be kept, therefore we are interested in doing research with the title "INVESTIGATION OF EFFECTIVE DOSE ESTIMATES NON CONTRAS CT-SCAN HEAD WITH CV A WITH SLICE CT-SCAN 128 SCAN LENGTH OF CHANGES IN UNIT RADIOLOGY IGD Hospital Dr.Soetomo SURABAYA". Objective: To determine the estimated effective dose of aCT-Scan none contrast head CT scan at 128 slice with cases of CV A to changes in the scan length in the ER Radiology Unit Dr. Soetomo. The method we use is observational research that is by observing the radiation dose and the factors that affect the brain CT scan is a scan length with CV A case using 128 slice CT scan. In this study workmanship processing techniques and data analysis done by collecting data from the patient's CT scan examination head with as many as 30 cases of CV A patient data to see mAs, pitch, rotation time, CTDivol, and dose length product (DLP). Then the data will be obtained DLP value received by the head of the organ. Then the results will be calculated value of the effective dose and will further analyzed the influence of the scan length and value of the radiation dose received by patients. The conclusion from this observation that the average yield value effective dose in radiological emergency Installation Dr. Soetomo with a scan length of 1 em below the skull base does not exceed the value of the standard dose limits for the head of which has been determined by the ICRP in 2007. Since the obtained results 1.9219053 mSv is less than 2 mSv.

Item Type: Thesis (Tugas Akhir D3)
Additional Information: KKA KK FV R. 09/15 Kar e
Uncontrolled Keywords: Ct-Scan, CVA, Scan Length, DosisEfektif
Subjects: R Medicine
Divisions: 15. Fakultas Vokasi > Departemen Kesehatan > D3 Radiologi
Creators:
CreatorsNIM
Ayu Ismi Kartikasari, -NIM0112J 0313020
Yahya Febri Ningtyas, -NIMOll2103130:J8
Rifka Sogiyana, -NIM01121 0313044
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorPramono, -NIDN-
Depositing User: sugiati
Date Deposited: 13 Mar 2023 08:44
Last Modified: 14 Mar 2023 07:14
URI: http://repository.unair.ac.id/id/eprint/120517
Sosial Share:

Actions (login required)

View Item View Item