The Differencess Of Discontinuitas Iud In Post Placental And Intra-Cesarean In Madiun

Melynda Trilamsari Putri and Ashon Sa'adi and Ivon Diah Wittiarika and Gadis Meinar Sari (2021) The Differencess Of Discontinuitas Iud In Post Placental And Intra-Cesarean In Madiun. Indonesian Midwifery and Health Sciences Journal, 5 (3). ISSN 2656-7806

[img] Text (Artikel)
23 artikel.pdf

Download (770kB)
[img] Text (Kualitas Karil & Kesesuaian Bidang Ilmu)
23 karil.pdf

Download (566kB)
[img] Text (Turnitin)
23 turnitin.pdf

Download (1MB)
Official URL: https://e-journal.unair.ac.id/IMHSJ/article/view/2...

Abstract

Abstract Background: Intra Uterine Device (IUD) which is placed after delivery of the placenta is an attempt to reduce the rate of population growth. However, the achievement is still very low, especially in the post-placental IUD insertion. It is this high expulsion rate that continues to be a concern for service providers, so this method is acceptable. The purpose of this study is to compare the sustainability of IUD acceptors in post-placental and intra-cesareann placement. Methods: The design of this study was cross sectional with an observational analytic method. Location of this research in the family planning clinic of Dr. Soedono Madiun Hospital, Banjarejo Health Center, Tawangrejo Health Center, and PMB Ny. “P” Madiun City in 2019.The sample used consecutive sampling as many as 114 acceptors. The independent variable was the time of IUD insertion. The dependent variable is the discontinuity of the IUD acceptor. The instrument used was the 2019 IUD acceptor medical record. The Fisher Exact Test on SPSS was used to perform data analysis. Results: From 114 acceptors, there was no difference in the discontinuity of IUD acceptors in post-placental and intra-cesarean placement (p=0.1). The incidence of expulsion was found in post-placental insertion (p=0.02). In intra-cesarean IUD acceptors more confirmed using ultrasound examination (p = 0.03). There was no perforation in both. Conclusion: There is no difference in IUD acceptor discontinuity in post-placental and intra-cesarean placement.

Item Type: Article
Subjects: R Medicine > R Medicine (General) > R5-920 Medicine (General)
Divisions: 01. Fakultas Kedokteran > Ilmu Faal
Creators:
CreatorsNIM
Melynda Trilamsari PutriNIM011911223001
Ashon Sa'adiUNSPECIFIED
Ivon Diah WittiarikaNIM010830437
Gadis Meinar SariNIDN0004056612
Depositing User: arys fk
Date Deposited: 20 Apr 2023 12:51
Last Modified: 20 Apr 2023 12:51
URI: http://repository.unair.ac.id/id/eprint/124244
Sosial Share:

Actions (login required)

View Item View Item