B Value Variation Using Adc Mapping Technique With Diffusion Weighted Imaging Sequence to Distinguish Musculoskeletal Tumor Malignancy

Celine Catharina Rosar, Celine and Rosy Setiawati, Rosy and Didik Soeharmanto, Didik and Lailatul Muqmiroh, Lailatul and Amillia Kartikasari, Amillia B Value Variation Using Adc Mapping Technique With Diffusion Weighted Imaging Sequence to Distinguish Musculoskeletal Tumor Malignancy. Malaysian Journal of Medicine and Health Sciences, 6. ISSN 2636-9346

[img] Text (Artikel)
08. Artikel.pdf

Download (2MB)
[img] Text (Kualitas Karil & Kesesuaian Bidang Ilmu)
8 karil.pdf

Download (77kB)
[img] Text (Turnitin)
08. turnitin.pdf

Download (2MB)
[img] Text (Bukti Korespondensi)
08. New Korespondensi.pdf

Download (319kB)
Official URL: https://medic.upm.edu.my/jurnal_kami/malaysian_jou...

Abstract

ABSTRACT Introduction: Diffusion Weighted Imaging (DWI) is a sequence which owned by MRI that used the diffusion of water molecules called Brownian motion. Accordingly, DWI is a noninvasive approach for investigating tumor histological content. The yield of ADC value influenced by b value parameter. The aim of this research is to oppose the diagnostic performance of DWI sequence by using b value of 800 s/mm2 and 1000 s/mm2 respectively at MRI 1,5 T for the indentification of clinically musculoskeletal tumors using ADC mapping as a quantitative marking tool. Methods: DWI has been done on 15 patients with soft tissue tumors and used two different b value of 800 s/mm2 and 1000 s/mm2 respectively. Then, it was placed ROI in a restricted area during post processing to produce ADC Mapping values. ROI measurement are taken to the solid section of the tumors. Results: ADC value when using b value of 800 s/mm2 is higher than using b value of 1000 s/mm2 (p < 0,05). The mean value of ADC on the use of b value of 800 s/mm2 is 2.50±0,04x10-3 while on the use of b value of 1000 s/mm2 is 1.96±0,03x10-3. Furthermore, b value in benign tumors group are higher than in malignant tumors group. Conclusion: ADC value was totally different when using different parameter of b value. And the best b value to distinguish malignant and benign musculoskeletal tumors is using b value of 800 s/mm2 .

Item Type: Article
Subjects: R Medicine > R Medicine (General) > R5-920 Medicine (General)
Divisions: 01. Fakultas Kedokteran > Radiologi
Creators:
CreatorsNIM
Celine Catharina Rosar, Celine151610383039
Rosy Setiawati, RosyNIDN0015027604
Didik Soeharmanto, DidikUNSPECIFIED
Lailatul Muqmiroh, LailatulUNSPECIFIED
Amillia Kartikasari, AmilliaUNSPECIFIED
Depositing User: arys fk
Date Deposited: 21 Apr 2023 01:57
Last Modified: 29 May 2023 07:04
URI: http://repository.unair.ac.id/id/eprint/124269
Sosial Share:

Actions (login required)

View Item View Item