Diagnostic accuracy of contrast and non-contrast 1.5 tesla magnetic resonance imaging for lumbar herniated nucleus pulposus based on surgical findings: A systematic review and meta-analysis of diagnostic test accuracy studies

Endra Wibisono Harmawan, - and Tedy Apriawan, Tedy and Eko Agus Subagio, Eko and Muhammad Faris, Muhammad and Sri Andreani Utomo, - and Budi Utomo, Budi and Abdul Hafid Bajamal, Abdul Diagnostic accuracy of contrast and non-contrast 1.5 tesla magnetic resonance imaging for lumbar herniated nucleus pulposus based on surgical findings: A systematic review and meta-analysis of diagnostic test accuracy studies. International Journal of Health Sciences, 6. pp. 692-711. ISSN e-ISSN: 2550-696X

[img] Text (Artikel)
17 Artikel.pdf

Download (841kB)
[img] Text (Kualitas Karil & Kesesuaian Bidang Ilmu)
17- Karil Review 1.pdf

Download (57kB)
[img] Text (Turnitin)
Turnitin 17.pdf

Download (3MB)
Official URL: https://scholar.unair.ac.id/en/publications/diagno...

Abstract

Abstract This study aims to provide the latest information regarding the accuracy of contrast and non-contrast 1.5 Tesla MRI in the diagnosis of lumbar Herniated Nucleus Pulposus (HNP) compared with surgical findings. We included studies with subjects diagnosed with lumbar HNP due to degenerative processes, preoperative 1.5 Tesla contrast, and non-contrast MRI and described the number of findings of MRI diagnostic tests (index test) on the actual conditions found during surgery (reference standard). We searched literature from 5 databases: ProQuest, Pubmed, Cochrane Library, Biomed Central, and ScienceDirect. The sensitivity and specificity of contrast and non-contrast 1.5 Tesla MRI ranged between 64-95% and 55-100% (95% CI) with the area under the curve above the threshold on the ROC curve. Two studies compared the accuracy of MRI and Computed Tomography (CT) myelography with a wider ROC curve on CT myelography than on MRI. The ROC curve which has a wide area under the curve above the threshold depicts the relationship between sensitivity and specificity, shows that contrast non-contrast 1.5 Tesla MRI has a good accuracy in HNP diagnostic.

Item Type: Article
Subjects: R Medicine > R Medicine (General) > R5-920 Medicine (General)
Divisions: 01. Fakultas Kedokteran > Ilmu Bedah Saraf
Creators:
CreatorsNIM
Endra Wibisono Harmawan, -UNSPECIFIED
Tedy Apriawan, TedyNIDN0002048107
Eko Agus Subagio, EkoNIDN8864800016
Muhammad Faris, MuhammadNIDN0013087610
Sri Andreani Utomo, -UNSPECIFIED
Budi Utomo, BudiNIDN0018055904
Abdul Hafid Bajamal, AbdulNIDN8999900020
Depositing User: arys fk
Date Deposited: 31 May 2023 08:29
Last Modified: 31 May 2023 08:29
URI: http://repository.unair.ac.id/id/eprint/126915
Sosial Share:

Actions (login required)

View Item View Item