Abstract
Penelitian ini bertujuan untuk mengetahui karakteristik dari komposit Co-Cr-HAP (Cobalt Implant Composite/CIC) karena variasi komposisi Co:Cr untuk aplikasi bahan implan. Perbandingan dari komposisi Co:Cr berturut-turut adalah (82%:18%), (79%:21%), (76%:24%), (73%:27%), (70%:30%) yang ditambahkan 5% HAP dari jumlah paduan Co-Cr. Proses pembuatan meliputi pencampuran, pressing dan sintering. Proses pencampuran bahan dibuat dengan menggunakan mesin milling dengan kecepatan 600 rpm selama 30 menit kemudian dipress pada tekanan 370 MPa dan sintering dilakukan pada suhu 1000C selama 3 jam. Hasil uji XRD menunjukkan pola difraksi yang membentuk fasa kristal dan munculnya lapisan oksida CoO, Co3O4 dan CrO2 pada permukaan CIC akibat dari proses sintering yang tidak vacum. Nilai kekerasan sampel antara 351,096 ± 13,339 kgf/mm2 sampai 490,130 ± 76,540 kgf/mm2. Kekuatan tekan bertambah seiring dengan penambahan komposisi Cr, nilai tertinggi ditunjukkan CIC dengan perbandingan komposisi Co:Cr sebesar 70% : 30% yaitu 102,979 ± 0,153 N/mm2. Uji pada sel fibroblast dengan metode assay MTT memperoleh hasil prosentase sel yang hidup tertinggi pada komposisi tereebut sebesar 95,837 %. Secara keseluruhan hasil karakterisasi CIC menunjukkan hasil yang baik, hal ini ditunjukkan oleh prosentase sel yang hidup masih diatas batas toleransi yaitu 60%. Translation: This study aims to determine the characteristics of the composite Co-Cr-HAP (Cobalt Composite Implant / CIC) because of variations in the composition of Co: Cr implanted material applications. Comparison of the composition of Co: Cr, respectively (82%: 18%), (79%: 21%), (76%: 24%), (73%: 27%), (70%: 30%) of added 5% HAP from the Co-Cr alloy. Manufacturing process involves mixing, pressing and sintering. The process of mixing ingredients produced using milling machines with a speed of 600 rpm for 30 minutes and then pressed at a pressure of 370 MPa and sintering carried out at a temperature of 1000C for 3 hours. XRD test results showed that the diffraction pattern of crystal form and the emergence of phase oxide layer CoO, Co3O4 and CrO2 on the surface of the CIC result of sintering processes that do not vacuum. Sample hardness value of 351.096 ± 13.339 kgf/mm2 to 490.130 ± 76.540 kgf/mm2. Press the power increases with the addition of the composition of Cr, the highest value indicated the composition of CIC in the ratio of Co: Cr by 70%: 30% of 102.979 ± 0.153 N/mm2. Test on fibroblast cells by MTT assay method obtained results that the percentage of living cells with the highest tereebut composition of 95.837%. Overall characterization of CIC showed good results, it is shown by the percentage of living cells is still above the tolerance limit of 60%..
Item Type: | Thesis (Skripsi) | ||||||
---|---|---|---|---|---|---|---|
Additional Information: | KKC KK MPF 38 10 Wij v | ||||||
Uncontrolled Keywords: | Cobalt Implant Composite | ||||||
Subjects: | Q Science > QC Physics > QC1-999 Physics | ||||||
Divisions: | 08. Fakultas Sains dan Teknologi > Fisika | ||||||
Creators: |
|
||||||
Contributors: |
|
||||||
Depositing User: | Turwulandari | ||||||
Date Deposited: | 25 Jan 2011 12:00 | ||||||
Last Modified: | 13 Jun 2017 21:50 | ||||||
URI: | http://repository.unair.ac.id/id/eprint/25974 | ||||||
Sosial Share: | |||||||
Actions (login required)
View Item |