SENSOR KIMIA UNTUK MENDETEKSI KROMIUM (VI) DALAM AIR LIMBAH ELEKTROPLATING MENGGUNAKAN REAGEN DIPHENYLCARBAZIDE.

Rahmatulloh, Arief, 080710431 (2011) SENSOR KIMIA UNTUK MENDETEKSI KROMIUM (VI) DALAM AIR LIMBAH ELEKTROPLATING MENGGUNAKAN REAGEN DIPHENYLCARBAZIDE. Skripsi thesis, UNIVERSITAS AIRLANGGA.

[img]
Preview
Text (ABSTRAK)
gdlhub-gdl-s1-2011-rahmatullo-20066-mpk111-k.pdf

Download (347kB) | Preview
[img] Text (FULLTEXT)
gdlhub-gdl-s1-2011-iflakhahdi-16815-mpk101-o.pdf
Restricted to Registered users only

Download (2MB) | Request a copy
Official URL: http://lib.unair.ac.id

Abstract

Pada penelitian ini telah dilakukan pembuatan sensor kimia untuk mendeteksi Cr6+ dalam air limbah elektroplating. Tujuan dari penelitian ini adalah mengetahui kemampuan dari sensor kimia untuk mendeteksi kromium (VI) ditinjau dari parameter validasinya, menentukan konsentrasi optimum reagen diphenylcarbazide dan pH optimum pada pendeteksian kromium (VI) menggunakan sensor tersebut serta menguji kemampuan sensor dalam penggunaannya untuk pendeteksian kromium (VI) dalam air limbah elektroplating. Hasil yang diperoleh dari optimasi konsentrasi reagen diphenylcarbazide adalah 0,1 % dengan pH optimumnya adalah pH 6. Panjang gelombang maksimum sensor kimia sebesar 542,5 nm. Uji selektivitas sensor dilakukan dengan menambahkan ion lain yang terdapat pada air limbah elektroplating seperti Cu2+ dan Zn2+ dengan perbandingan 1:1, 1:10, 1:100. Hasil penelitian menunjukkan bahwa ion Cu2+ dan Zn2+ mengganggu pengukuran mulai perbandingan 1:1. Daerah linearitas sensor pada konsentrasi 0,0 ppm sampai 1,0 ppm, dengan limit deteksi sebesar 0,03 ppm, nilai koefisien variasinya adalah 2,21%, sedangkan nilai recovery yang didapat sebesar 100,91 %. Translation: In this research the production of chemical sensor to detect Cr6+ in electroplating wastewater was done. Objective of this research are reviewing the capability of chemical sensor to detect Cr6+ in terms of validation parameters, to determine the concentration of diphenylcarbazide reagent and pH optimation of chemical sensor, and to test the ability of the sensor in its use for the detection of chromium (VI) in electroplating waste water. The results obtained from optimization of reagent concentrations diphenylcarbazide is 0.1% with a pH optimum is 6. The maximum wavelength of chemical sensor is 542.5 nm. Selectivity of test sensors is done by adding other ion that present in electroplating wastewater such as Cu2+ and Zn2+ with a ratio of 1:1, 1:10, 1:100. The results showed that the ions Cu2+ and Zn2+ disrupt the measurement starting ratio of 1:1. Linearity of the sensor region at a concentration of 0.0 ppm to 1.0 ppm, with a detection limit of 0.03 ppm, the value of the variation coefficient is 2.21%, while recovery values obtained at 100.91 %.

Item Type: Thesis (Skripsi)
Additional Information: KKC KK MPK 11/11 RAH s
Subjects: Q Science > QD Chemistry
Divisions: 08. Fakultas Sains dan Teknologi > Kimia
Creators:
CreatorsNIM
Rahmatulloh, Arief, 080710431UNSPECIFIED
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorGanden Supriyanto, Dr. rer. nat. , M.ScUNSPECIFIED
Thesis advisorUNSPECIFIEDUNSPECIFIED
Depositing User: Turwulandari
Date Deposited: 06 Oct 2011 12:00
Last Modified: 29 Jul 2016 09:05
URI: http://repository.unair.ac.id/id/eprint/25987
Sosial Share:

Actions (login required)

View Item View Item