MANAJEMEN PENGENDALIAN PAPARAN PANAS TERHADAP KONSUMSI AIR MINUM TENAGA KERJA REGU A SHIF PAGI BAGIAN FORMING PT. IGLAS (PERSERO) GRESIK

NURHAYATI, 090810621 M (2011) MANAJEMEN PENGENDALIAN PAPARAN PANAS TERHADAP KONSUMSI AIR MINUM TENAGA KERJA REGU A SHIF PAGI BAGIAN FORMING PT. IGLAS (PERSERO) GRESIK. Thesis thesis, UNIVERSITAS AIRLANGGA.

[img]
Preview
Text (ABSTRAK)
gdlhub-gdl-s2-2011-nurhayati-19471-tkm151-k.pdf

Download (89kB) | Preview
[img] Text (FULL TEXT)
gdlhub-gdl-s2-2011-nurhayati-16241-tkm151-m.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
Official URL: http://lib.unair.ac.id

Abstract

Hot climate in the workplace is one of the dangerous factors that can negatively impact the health and safety of workers. When workers work continuously in hot, it will cause dehydration which in turn can affect work productivity. To overcome these problems, control of heating exposure can be done in various ways, including the techniques of elimination, substitution, isolation, administrative and Personal Protective Equipment (PPE). Control of the administration through the provision of adequate drinking water for workers is one of the easiest ways to apply for this condition. The purpose of this study was to determine the roles and responsibilities of corporate management to control exposure to heat, the distribution policy, the supervision of the use, follow up and effective use of drinking water for the workers who worked in a Group of morning shift on Forming part of PT. IGLAS (Persero), Gresik. The study was descriptive. The sample size was taken 15 workers, all workers are male, most of the workers age 35 years old. Primary data were obtained by measurement, observation and interviews using a questionnaire. Secondary data obtained from company management. The workers body’s temperature after work between 37.9ºC- 38.4ºC, The measurement results of ISBB (Index Temperature Ball Wet) show 34.8º-38.4ºC. indicated the value has exceeded the TLV (Threshold Limit Value) for the work medium load is (26.7ºC) who works continuously. According to The Decree of Manpower Minister no. Kep-51/MEN/1999 of Index Temperature Ball Wet Physic Factor At Workplace. The study was conducted on September 20, 2010 to January 31 st, 2011

Item Type: Thesis (Thesis)
Additional Information: KKC KK TKM 15 /11 Nur m
Uncontrolled Keywords: The role of corporate management, exposure to heat, drinking water
Subjects: Q Science > QD Chemistry > QD241-441 Organic chemistry
R Medicine > RA Public aspects of medicine > RA1-1270 Public aspects of medicine > RA1-418.5 Medicine and the state > RA407-409.5 Health status indicators. Medical statistics and surveys
Divisions: 10. Fakultas Kesehatan Masyarakat > Keselamatan dan Kesehatan Kerja
Creators:
CreatorsNIM
NURHAYATI, 090810621 MUNSPECIFIED
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorM. Sulaksmono, dr.,M.S.,MPH.,Sp.OKUNSPECIFIED
Thesis advisorMulyono, SKM.,M.KesUNSPECIFIED
Depositing User: Nn Anisa Septiyo Ningtias
Date Deposited: 2015
Last Modified: 11 Jul 2016 05:13
URI: http://repository.unair.ac.id/id/eprint/37959
Sosial Share:

Actions (login required)

View Item View Item