STUDI KOMPARASI PENGARUH PENURUNAN kV TERHADAP DOSIS DAN KUALITAS GAMBAR DARI BEBERAPA MODALITAS CT SCAN MULTI DETEKTOR

ALFA MUBDI AMANDO, 151510383043 (2016) STUDI KOMPARASI PENGARUH PENURUNAN kV TERHADAP DOSIS DAN KUALITAS GAMBAR DARI BEBERAPA MODALITAS CT SCAN MULTI DETEKTOR. Skripsi thesis, Universitas Airlangga.

[img]
Preview
Text (abstrak)
FV.RD.10-16 Ama s abstrak.pdf

Download (521kB) | Preview
[img] Text (fulltext)
FV.RD.10-16 Ama s.pdf
Restricted to Registered users only

Download (2MB) | Request a copy
Official URL: http://lib.unair.ac.id

Abstract

This study aims to know the effect of a decrease in the 120 kV, 100 kV and 80 kV the estimated value of DLP (Dose Length Product) and image quality in CT 16 slice, 64 slice and 128 slice by applying the same parameter values on several factors eksposi (mA), pitch, beam width and rotation time. The method used in this research is a comparative descriptive method with quantitative approach, using 3 kV different variations on CT Scan 16, 64 and 128 slice and produce nine samples. With media research is a head phantom. Positioning the head phantom on the examining table and set center point like a CT scan of the head. Next, fill the experimental data, each experiment 1, 2, and 3. Then change the 3 kV different variations and fills the same parameter values on each trial. After the scanning process. As a proof based on the calculation results can be seen that the "Sig" is smaller than the error rate (α) = 0.05 then it can be concluded that refused so with a confidence level of 95% can be said that kV significant effect on DLP on CT Scan 16, 64 and 128 slice. While the image quality assessment questionnaires to PPDS Radiology can be concluded that the results of the assessment questionnaires in terms of resolution and the anatomical structure of the bones clearly with the largest average are at 120 kV with the criteria of excellent results and vice versa average yield was lowest for the 80 kV with poor results as well. From the results of this research can be concluded that the decline kV have an impact on the estimated value of DLP. So, the smaller kV is given, then the estimated value of DLP is getting smaller. And the greater the value of kV is given, then the greater the estimated value of DLP. Keyword: kV, mA, pitch, beam width, rotation time, DLP, Slice

Item Type: Thesis (Skripsi)
Additional Information: KKA KK FV.RD.10-16 Ama s
Uncontrolled Keywords: kV, mA, pitch, beam width, rotation time, DLP, Slice
Subjects: R Medicine > RC Internal medicine > RC71-78.7 Examination. Diagnosis Including radiography
Divisions: 15. Fakultas Vokasi > Departemen Kesehatan > D4 Alih Jenjang Radiologi
Creators:
CreatorsNIM
ALFA MUBDI AMANDO, 151510383043UNSPECIFIED
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorAnggraini Dwi Sensusiati, Dr. Hj., dr., Sp.Rad (K)UNSPECIFIED
Thesis advisorPramono, S.STUNSPECIFIED
Depositing User: Tatik Poedjijarti
Date Deposited: 28 Feb 2017 01:25
Last Modified: 28 Feb 2017 01:25
URI: http://repository.unair.ac.id/id/eprint/53678
Sosial Share:

Actions (login required)

View Item View Item