PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA

ULIL ALIIFAH PUTRI, 15161383046 (2018) PERBANDINGAN VARIASI REDUCE DOSE DAN ITERATIVE RECONSTRUCTION (IR) DALAM MENENTUKAN MINIMALISASI DOSE LENGTH PRODUCT (DLP) DAN IMAGE NOISE CT SCAN KEPALA. Skripsi thesis, Universitas Airlangga.

[img] Text (Abstrak)
FV.RD. 10-18 Put p Abstrak.pdf

Download (120kB)
[img] Text (Fulltext)
FV.RD. 10-18 Put p.pdf
Restricted to Registered users only until 2 January 2022.

Download (2MB) | Request a copy
Official URL: http://lib.unair.ac.id

Abstract

Background: Minimalization of Dose Length Product (DLP) and image noise can be obtained from the use of appropriate methods with the examination done. One method to minimize the radiation dose is Reduce Dose. Then there are several methods to reduce image noise and Iterative Reconstruction (IR) method is used. One of the Iterative Reconstruction methods found in the Philips 128 Slices MSCT tool is iDose. This study intends to obtain an optimal Reduce Dose level in reducing dosage and iDose levels capable of minimizing image noise. Purpose: To know the differences of Dose Length Product (DLP) and Image Noise by using variation method of Reduce Dose and Iterative Reconstruction (IR). Result: In the increasing variation of Reduce Dose, there is a difference of Dose Length Product (DLP) which is also increasing. Increasing DLP value is in line with the decreased image noise value. The most minimal increase in the dose of radiation is found in the variation of Reduce Dose 34 with a 2.2% increase. The most minimal image noise value is at iDose level 5. Among the three variations of Reduce Dose, the level that reduces image noise most is Reduce Dose 34. Conclusion:There are several differences of Dose Length Product (DLP) and Image noise values with variation of Reduce Dose and Iterative Reconstruction methods. Based on experiment, Reduce Dose 34 and iDose 5 has chosen as the optimal level in radiation dose and image noise. This levels gives optimal dose with minimal image noise values.

Item Type: Thesis (Skripsi)
Additional Information: KKA KK FV.RD. 10-18 Put p
Uncontrolled Keywords: Reduce Dose, Iterative Reconstruction, Dose Length Product, Image Noise
Subjects: R Medicine > RC Internal medicine > RC71-78.7 Examination. Diagnosis Including radiography
Divisions: 15. Fakultas Vokasi > Departemen Kesehatan > D4 Alih Jenjang Radiologi
Creators:
CreatorsNIM
ULIL ALIIFAH PUTRI, 15161383046UNSPECIFIED
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorAnggraini Dwi S, Dr. Hj., dr., Sp.Rad (K),UNSPECIFIED
Thesis advisorBudi Prijo W, S.ST.MM,UNSPECIFIED
Depositing User: Tatik Poedjijarti
Date Deposited: 02 Jan 2019 02:50
Last Modified: 02 Jan 2019 02:50
URI: http://repository.unair.ac.id/id/eprint/77438
Sosial Share:

Actions (login required)

View Item View Item