ANALISIS PERBANDINGAN HASIL CITRA PANKREAS FASE VENA PORTA PADA CT SCAN ABDOMEN KONTRAS TANPA DAN DENGAN MENGGUNAKAN MINIMUM INTENSITY PROJECTION PADA CT SCAN 64 SLICE

MARIA RAMANDITA, 151610383049 (2018) ANALISIS PERBANDINGAN HASIL CITRA PANKREAS FASE VENA PORTA PADA CT SCAN ABDOMEN KONTRAS TANPA DAN DENGAN MENGGUNAKAN MINIMUM INTENSITY PROJECTION PADA CT SCAN 64 SLICE. Skripsi thesis, Universitas Airlangga.

[img] Text (Abstrak)
FV.RD. 12-18 Ram a Abstrak.pdf

Download (82kB)
[img] Text (Fulltext)
FV.RD. 12-18 Ram a.pdf
Restricted to Registered users only until 2 January 2022.

Download (2MB) | Request a copy
Official URL: http://lib.unair.ac.id

Abstract

Background: Minimum Intensity Projection is a post-proccesing technique on CT Scan that useful for showing structures with low Hounsfiled Unit (HU) values such as pancreas. To demonstrate the anatomy and pathology of the pancreatic organs, a contrast CT scan was performed on pancreatic phase but pancreatic phase was rarely used, so it was replaced by the portal venous phase, but this technique is still rarely used among the radiographers. Objective: This study aimed to prove the image of the portal venous pancreatic vein on contrast contrast CT scan by using minimum intensity projection (MinIP) on CT scan 64 slices will produce a more optimal image than without the minimum intensity projection (MinIP). Methods: This study is a retrospective study with an observational analytic method to assess differences of pancreatic image in contrasting contrast CT scans with and with MinIP reforms on CT 64 slice modalities Philips Briliance. 30 images as samples, with the criteria set by the researchers. The image will be post proccesing without and by using MinIP reformat. Image results will be evaluated by two radiologist, then the data obtained will be tabulated and processed using SPSS software version 17. Result: From this research obtained the result that MinIP reformat able to produce pancreas image more optimal than image without MinIP reformat on CT scan 64 slice and shows a significant difference. The assessed images are the pancreatic duct, the pancreatic density boundary with the superior mesenteric veins, the pancreatic border with the duodenum, the pancreatic image homogeneity level and the overall result of pancreatic borders and edges. Overall assessment of the image has an improvement with the MinIP but for the homogeneity of pancreatic images decreased, this is because MinIP will make the density in the CT scan image will be reduced so it will look darker so the image is more homogeneous. Conclusions: There was a significant difference between pancreatic venous porta port results in contrasting CT scans of the abdomen without and with MinIP reformat.

Item Type: Thesis (Skripsi)
Additional Information: KKA KK FV.RD. 12-18 Ram a
Uncontrolled Keywords: Minimum Intensity Projection (MinIP), CT scan abdomen contrast and portal vein phase.
Subjects: R Medicine > RC Internal medicine > RC71-78.7 Examination. Diagnosis Including radiography
Divisions: 15. Fakultas Vokasi > Departemen Kesehatan > D4 Alih Jenjang Radiologi
Creators:
CreatorsNIM
MARIA RAMANDITA, 151610383049UNSPECIFIED
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorLailatul Muqmiroh, Dr., Sp. Rad (K),UNSPECIFIED
Thesis advisorPramono, S.STUNSPECIFIED
Depositing User: Tatik Poedjijarti
Date Deposited: 02 Jan 2019 03:00
Last Modified: 02 Jan 2019 03:00
URI: http://repository.unair.ac.id/id/eprint/77441
Sosial Share:

Actions (login required)

View Item View Item