Design and Development of Device to measure Body Fat using Multi-frequency Bio-impedance Method

Ain, Khusnul and Soelistiono, Soegianto and Wibowo, R. Arif and Muniroh, Lailatul and Anggono, Tri and Sari, W.WulanPuspita (2018) Design and Development of Device to measure Body Fat using Multi-frequency Bio-impedance Method. In: he 8th International Conference on Theoretical and Applied Physics.

[img] Text (Full Text)
7 lailatul muniroh.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text (Abstrak)
7 abstrak lailatul muniroh.pdf

Download (58kB)
Official URL: https://iopscience.iop.org/article/10.1088/1742-65...

Abstract

Obesity is the beginning of the emergence of various chronic diseases such as stroke, heart failure, diabetes, and so on. Therefore, obesity becomes one of the indicators to know the health condition. Obesity can be known from Body Mass Index (BMI). BMI only considers weight and height, while obesity is related to fat composition, so this information is less valid. One method that can calculate body fat composition is Bioelectrical Impedance Analysis (BIA). BIA works by injecting a constant current into the body and measuring its voltage. This research designs and develops device to measure the body fat content with multi-frequency bio-impedance method. The study was conducted by generating a multi-frequency sine wave from AD9850 accompanied by a DC block so that an AC sine wave was generated. It would be converted into a constant current on VCCS. The electric current is injected into the body through two electrodes and the voltage was tapped by two another electrodes. The voltage are processed by instrument amplifier (AD620). AC signal from AD620 is converted to DC signal by AD536. Analog data is processed by ADC in the microcontroller so that the body impedance is obtained. The device was tested on 7 volunteers. The calculation of body fat was compared with standard OMRON HBF 214 device. In this research we got the linearity equation y = 0.999x + 0.161 with R2 = 0.997 as the result of correlation between the body fat from reference (x) and the measurement of body fat from the device was developed (y).

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: body fat, multi frequency, bio-impedance.
Subjects: R Medicine
Divisions: 10. Fakultas Kesehatan Masyarakat
Creators:
CreatorsNIM
Ain, KhusnulUNSPECIFIED
Soelistiono, SoegiantoUNSPECIFIED
Wibowo, R. ArifUNSPECIFIED
Muniroh, LailatulUNSPECIFIED
Anggono, TriUNSPECIFIED
Sari, W.WulanPuspitaUNSPECIFIED
Depositing User: Tn Chusnul Chuluq
Date Deposited: 24 May 2019 07:45
Last Modified: 24 May 2019 07:45
URI: http://repository.unair.ac.id/id/eprint/82781
Sosial Share:

Actions (login required)

View Item View Item