Fatih El Qorimah (2019) Studi Komparasi Metode Statistical Iterative Reconstruction Dengan Model-Based Iterative Reconstruction Pada Kualitas Citra Ct Scan Abdomen Polos. Skripsi thesis, UNIVERSITAS AIRLANGGA.
Text
1. HALAMAN JUDUL.pdf Download (282kB) |
|
Text
2. ABSTRAK.pdf Download (47kB) |
|
Text
3. DAFTAR ISI.pdf Download (79kB) |
|
Text
4. BAB I PENDAHULUAN.pdf Download (98kB) |
|
Text
5. BAB II TINJAUAN PUSTAKA.pdf Restricted to Registered users only until 17 February 2023. Download (291kB) | Request a copy |
|
Text
6. BAB III METODE PENELITIAN.pdf Restricted to Registered users only until 17 February 2023. Download (138kB) | Request a copy |
|
Text
7. BAB IV HASIL PENELITIAN.pdf Restricted to Registered users only until 17 February 2023. Download (342kB) | Request a copy |
|
Text
8. BAB V PEMBAHASAN.pdf Restricted to Registered users only until 17 February 2023. Download (83kB) | Request a copy |
|
Text
9. BAB VI PENUTUP.pdf Restricted to Registered users only until 17 February 2023. Download (41kB) | Request a copy |
|
Text
10. DAFTAR PUSTAKA.pdf Download (104kB) |
|
Text
11. LAMPIRAN.pdf Restricted to Registered users only until 17 February 2023. Download (479kB) | Request a copy |
Abstract
Pemeriksaan CT Scan membutuhkan dosis radiasi yang tinggi. Reduce dose merupakan inovasi alat CT Scan yang digunakan untuk mengurangi dosis radiasi pada pemeriksaan yang memberikan pengaruh terhadap kualitas citra. Iterative reconstruction (IR) merupakan rekonstrusi untuk meningkatkan kulitas citra pada penggunaan dosis rendah. IR memilki dua metode yaitu Statistical Iterative Reconstruction dan Model-Based Iterative Reconstruction. Tujuan dari penelitian ini Mengetahui perbandingan penggunaan metode statistical iterative reconstruction dengan model-based iterative reconstruction terhadap kualitas citra CT scan Abdomen polos. Dari 20 sampel didapat 12 (60%) perempuan dan 8 (40%) laki laki. Setiap sampel direkonstrusi menggunakan statistical iterative reconstruction (iDose4 level 3 dan 4) dan model-based iterative reconstruction (IMR ST level 1 dan 3). Dilakukan penialaian SNR pada (hepar, aorta abdominal, ginjal, dan dinding abdomen dan secara Visual oleh dua dokter spesialis radiologi pada (diding abdomen, parenkim hepar, parenkim lien, aorta abdominal dan ginjal). Hasil penelitian ini berdasarkan penilaian dengan SNR dan penilaian secara visual terdapat perbedaan yang signifikan (p<0.05) antara statistical iterative reconstruction dan model-based iterative reconstruction. Dengan rata rata nilai SNR tertinggi dengan metode model-based iterative reconstruction pada IMR ST level 3. Sedangkan penilaian secara visual nilai rata rata tertinggi statistical iterative reconstruction iDose4 level 4.
Item Type: | Thesis (Skripsi) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Additional Information: | KKA KK FV.RD 04/20 Qor s | |||||||||
Uncontrolled Keywords: | Iterative reconstruction, iDose4,IMR, CT scan Abomen. | |||||||||
Subjects: | R Medicine > RM Therapeutics. Pharmacology > Including massage, exercise, occupational therapy, hydrotherapy, phototherapy, radiotherapy, thermotherapy, electrotherapy | |||||||||
Divisions: | 15. Fakultas Vokasi > Departemen Kesehatan > D4 Alih Jenjang Radiologi | |||||||||
Creators: |
|
|||||||||
Contributors: |
|
|||||||||
Depositing User: | Dwi Marina | |||||||||
Date Deposited: | 17 Feb 2020 08:28 | |||||||||
Last Modified: | 17 Feb 2020 08:28 | |||||||||
URI: | http://repository.unair.ac.id/id/eprint/94331 | |||||||||
Sosial Share: | ||||||||||