Zakkya Novi Ainur Riza (2020) Aplikasi Metode Optik Untuk Mendeteksi Gas Hidrogen. Skripsi thesis, UNIVERSITAS AIRLANGGA.
Text (HALAMAN JUDUL)
1. HALAMAN JUDUL.pdf Download (81kB) |
|
Text (ABSTRAK)
2. ABSTRAK.pdf Download (72kB) |
|
Text (DAFTAR ISI)
3. DAFTAR ISI.pdf Download (104kB) |
|
Text (BAB I)
4. BAB I PENDAHULUAN.pdf Download (22kB) |
|
Text (BAB II)
5. BAB II TINJAUAN PUSTAKA.pdf Restricted to Registered users only until 8 January 2024. Download (1MB) | Request a copy |
|
Text (BAB III)
6. BAB III METODE PENELITIAN.pdf Restricted to Registered users only until 8 January 2024. Download (26kB) | Request a copy |
|
Text (BAB IV)
7. BAB IVHASIL DAN PEMBAHASAN.pdf Restricted to Registered users only until 8 January 2024. Download (33kB) | Request a copy |
|
Text (BAB V)
8. BAB V PENUTUP.pdf Restricted to Registered users only until 8 January 2024. Download (23kB) | Request a copy |
|
Text (DAFTAR PUSTAKA)
9. DAFTAR PUSTAKA.pdf Download (68kB) |
|
Text (PERMOHONAN EMBARGO)
10. PERMOHONAN EMBARGO.pdf Restricted to Registered users only Download (203kB) | Request a copy |
Abstract
Hydrogen is a flammable gas, at standard temperatures and pressures hydrogen gas is colorless, odorless, non-metallic so it can not be detected by the human senses. Therefore we need a instrument that can provide fast and accurate responses to detect its presence and measure its concentration. Optical technology by utilizing optical fibers and interferometers has been developed for hydrogen gas sensors because they are easily fabricated, low cost but still have high potential to detect hydrogen and able to provide high sensitivity. The method to increase the sensitivity and response time of the sensor is by adding a film Pd/Pt as catalyst layer in the hydrogen sensor. But the addition of Pd layer in the sensor is influenced by its thickness, where the thicker Pd will give the sensor the higher sensitivity but reduces the speed of sensor response time. The best sensitivity has been obtained is 0,99 nm/% using a Pd thickness of 70 μm and the fastest response time is 15 seconds using a Pd thickness of 3 nm.
Item Type: | Thesis (Skripsi) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Additional Information: | KKC KK MPF. 32-20 Riz a | |||||||||
Uncontrolled Keywords: | hydrogen, optical fiber, interferometer, sensitivity, response time. | |||||||||
Subjects: | Q Science > QD Chemistry > QD450-801 Physical and theoretical chemistry | |||||||||
Divisions: | 08. Fakultas Sains dan Teknologi > Fisika | |||||||||
Creators: |
|
|||||||||
Contributors: |
|
|||||||||
Depositing User: | Tatik Poedjijarti | |||||||||
Date Deposited: | 08 Jan 2021 00:25 | |||||||||
Last Modified: | 08 Jan 2021 00:25 | |||||||||
URI: | http://repository.unair.ac.id/id/eprint/102706 | |||||||||
Sosial Share: | ||||||||||
Actions (login required)
View Item |