Evaluasi Metode Helical Dan Axial Dengan Variasi mAs Dan kV Pada CT-Scan Fantom Terhadap Kualitas Citra

Erni Dwi Sinta (2020) Evaluasi Metode Helical Dan Axial Dengan Variasi mAs Dan kV Pada CT-Scan Fantom Terhadap Kualitas Citra. Skripsi thesis, UNIVERSITAS AIRLANGGA.

[img] Text (HALAMAN JUDUL)
1. HALAMAN JUDUL.pdf

Download (260kB)
[img] Text (ABSTRAK)
2. ABSTRAK.pdf

Download (253kB)
[img] Text (DAFTAR ISI)
3. DAFTAR ISI.pdf

Download (300kB)
[img] Text (BAB I)
4. BAB I PENDAHULUAN.pdf

Download (252kB)
[img] Text (BAB II)
5. BAB II TINJAUAN PUSTAKA.pdf
Restricted to Registered users only until 11 January 2024.

Download (554kB) | Request a copy
[img] Text (BAB III)
6. BAB III METODE PENELITIAN.pdf
Restricted to Registered users only until 11 January 2024.

Download (321kB) | Request a copy
[img] Text (BAB IV)
7. BAB IVHASIL DAN PEMBAHASAN.pdf
Restricted to Registered users only until 11 January 2024.

Download (501kB) | Request a copy
[img] Text (BAB V)
8. BAB V KESIMPULAN DAN SARAN.pdf
Restricted to Registered users only until 11 January 2024.

Download (239kB) | Request a copy
[img] Text (DAFTAR PUSTAKA)
9. DAFTAR PUSTAKA.pdf

Download (202kB)
[img] Text (LAMPIRAN)
10. LAMPIRAN.pdf
Restricted to Registered users only until 11 January 2024.

Download (1MB) | Request a copy
[img] Text (PERMOHONAN EMBARGO)
11. PERMOHONAN EMBARGO.pdf
Restricted to Registered users only

Download (44kB) | Request a copy
Official URL: http://www.lib.unair.ac.id

Abstract

Research On The Evaluation Of Helical And Axial Methods With Variations In Mas (140, 200 Dan 260) Dan Kv (80 Dan 120) On CT-Scan Phantom On Image Quality. The Study Was Conducted Using Phantom As A Substitute For Patients, Because In This Study Requires Repeated Scanning. This Study Aims To Determine The Effect Of The Acquisition Method, Mas And Kv On The Image Results On The Head Fantom. Compare Image Quality Based On Noise.. Each Image Is Carried Out With The Region Of Interest (ROI) Results At 5 Points On Each Slice To Get The Standard Deviation As A Representation Of The Noise Value. Noise Value Is Put Together In Graphical Form And Made A Description Then Compared With The Results Of The One Way Anova Test, Significant That Is P = 0.00 For The Overall Noise Value Data Helical And Axial Methods. The Results Of The SPSS Show That The Influence Of The Scanning Method Is A Significant Difference. This Means That There Are Differences In The Scanning Method Of The Noise Value Of The Image. Noise Value Indicates That The Optimal Helical Scanning Method Is To Produce The Optimal Image.

Item Type: Thesis (Skripsi)
Additional Information: KKC KK MPF. 40-20 Sin e
Uncontrolled Keywords: CT-Scan, Phantom, Noise, Scanning Method
Subjects: Q Science > QD Chemistry > QD450-801 Physical and theoretical chemistry
Divisions: 08. Fakultas Sains dan Teknologi > Fisika
Creators:
CreatorsNIM
Erni Dwi SintaNIM081611333096
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorSuhariningsihNIDN0027065203
Thesis advisorSuryani Dyah AstutiNIDN0008046902
Depositing User: Tatik Poedjijarti
Date Deposited: 11 Jan 2021 01:14
Last Modified: 11 Jan 2021 01:14
URI: http://repository.unair.ac.id/id/eprint/102841
Sosial Share:

Actions (login required)

View Item View Item