Comparative efficacy and safety of holmium laser enucleation of the prostate (HoLEP) using moses technology and standard HoLEP: A systematic review, meta-analysis, and meta-regression

Muhammad Zaniar Ramadhani, - and Yudhistira Pradnyan Kloping, - and Ilham Akbar Rahman, - and Niwanda Yogiswara, - and Johan Renaldo, - and Soetojo, - (2022) Comparative efficacy and safety of holmium laser enucleation of the prostate (HoLEP) using moses technology and standard HoLEP: A systematic review, meta-analysis, and meta-regression. Annals of Medicine and Surgery, 81. pp. 1-10. ISSN 20490801

[img] Text (Similarity)
Similarity 4.pdf

Download (3MB)
[img] Text (Artikel)
Artikel 4_compressed.pdf

Download (1MB)
[img] Text (Karil)
Karil 4.pdf

Download (1MB)
Official URL: https://www.sciencedirect.com/science/article/pii/...

Abstract

Purpose The use of HoLEP was associated with steep learning curve thus prolonging operative procedure. The problem of learning curve could be solved with the invention of Moses HoLEP. This study aimed to evaluate the comparison of efficacy and safety between Moses HoLEP and standard HoLEP in BPH patient. Materials and methods Systematic search was carried out using PRISMA guideline. Pubmed, Scopus and Embase were searched to collect randomized controlled trials and observational studies. Quantitative analysis was performed to evaluate the comparison in intraoperative, postoperative and complications characteristics. RevMan 5.4 and STATA were used in data analysis. Results Total of 7 studies (1226 patients) were included. Regarding intraoperative characteristics, Moses HoLEP provided significantly shorter enucleation time (MD: 3.00, 95% CI: 5.57 to −0.43, p = 0.02), shorter hemostasis time (MD: 3.79, 95% CI: 5.23 to −2.34, p < 0.00001), and shorter laser use time (MD: 2.79, 95% CI: 5.03 to −0.55, p = 0.01). For postoperative characteristics, Moses HoLEP possessed significantly lower PVR (MD -34.57, 95% CI -56.85 to −12.30, p = 0.002). Overall complication was higher in standard HoLEP although the result was not significant (MD 0.68, 95%CI: 0.38 to 1.21, p = 0.19). Moses HoLEP possessed more superiority over standard HoLEP regarding shorter hemostasis time with the increasing of prostate size (coefficient −0.894, p = 0.044). Conclusion Moses HoLEP demonstrated shorter enucleation time, shorter hemostasis time and shorter laser use time. Moses HoLEP also possessed lower PVR. There were no safety issues in Moses HoLEP compared with standard HoLEP.

Item Type: Article
Uncontrolled Keywords: Prostatic hyperplasia, Moses HoLEP, Holmium laser enucleation of the prostate, HoLEP
Subjects: R Medicine > R Medicine (General)
R Medicine > RC Internal medicine > RC870-923 Diseases of the genitourinary system. Urology
Divisions: 01. Fakultas Kedokteran > Urologi
Creators:
CreatorsNIM
Muhammad Zaniar Ramadhani, -UNSPECIFIED
Yudhistira Pradnyan Kloping, -UNSPECIFIED
Ilham Akbar Rahman, -UNSPECIFIED
Niwanda Yogiswara, -UNSPECIFIED
Johan Renaldo, -UNSPECIFIED
Soetojo, -NIDN0008065604
Depositing User: arys fk
Date Deposited: 29 Jan 2023 23:40
Last Modified: 29 Jan 2023 23:40
URI: http://repository.unair.ac.id/id/eprint/119750
Sosial Share:

Actions (login required)

View Item View Item