Miratul Khasanah, .- and Alfa Akustia Widati,, .- and Usreg Sri Handajani,, .- and Muji Harsini, .- and Bahrotul Ilmiah,, .- and Irene Dinda Oktav, .- (2020) Imprinted Zeolite Modified Carbon Paste Electrode as a Selective Sensor for Blood Glucose Analysis by Potentiometry. Indonesian Journal of Chemistry, 20 (6). pp. 1301-1310. ISSN P-ISSN:1411-9420; E-ISSN: 2460-1578
|
Text (Fulltext)
C03. Fulltext.pdf Download (6MB) |
|
|
Text (Penilaian dan Validasi)
C03. Penilaian dan Validasi.pdf Download (924kB) |
|
|
Text (Similarity)
C03. Similarity.pdf Download (2MB) |
|
|
Text (Bukti Korespondensi)
C03. Bukti Korespondensi.pdf Download (202MB) |
Abstract
Imprinted zeolite modified carbon paste (carbon paste-IZ) electrode had been developed as a sensor to analyze blood glucose content by potentiometry. The used zeolite was Lynde Type A (LTA) that synthesized with a mole ratio of Na2O, Al2O3, SiO2 and H2O of 4:1:1.8:270, respectively while non-imprinted zeolite was prepared with a mole ratio of glucose/Si of 0.0306. Glucose was then extracted from the zeolite framework using hot water (80 °C) to produce imprinted zeolite (IZ). The carbon paste-IZ electrode prepared from activated carbon, paraffin pastilles, and IZ with a mass ratio of 5:4:1 showed the best performance. The modified electrode demonstrated the measurement range of 10–4-10–2 M, the Nernst factor of 29.55 mV/decade, the response time less than 120 s, and the detection limit of 5.62 × 10–5 M. Ascorbic acid, uric acid, urea and creatinine did not interfere on the glucose analysis by potentiometry. Comparison test with spectrophotometry showed an accuracy of (90.7 ± 1.4)% (n = 5), while the application of the electrode to analyze five spiked serum samples showed recovery of (92.2 ± 1.3)% (n = 5). The electrode was stable for up to 9 weeks (168 times usage). Based on its performance, the developed electrode can be applied to analyze glucose in human serum sample and recommended for used in the medical field.
| Item Type: | Article | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Uncontrolled Keywords: | blood glucose; carbon paste electrode; imprinted zeolite; potentiometric sensor | ||||||||||||||
| Subjects: | Q Science Q Science > QD Chemistry Q Science > QD Chemistry > QD71-142 Analytical chemistry |
||||||||||||||
| Divisions: | 08. Fakultas Sains dan Teknologi > Kimia | ||||||||||||||
| Creators: |
|
||||||||||||||
| Depositing User: | Mr Vega Andi Budiman | ||||||||||||||
| Date Deposited: | 09 May 2023 00:39 | ||||||||||||||
| Last Modified: | 03 Jun 2023 07:16 | ||||||||||||||
| URI: | http://repository.unair.ac.id/id/eprint/125974 | ||||||||||||||
| Sosial Share: | |||||||||||||||
Actions (login required)
![]() |
View Item |