Imprinted Zeolite Modified Carbon Paste Electrode as A Selective Potentiometric Sensor for Blood Glucose

Miratul Khasanah, .- and Alfa Akustia Widati, .- and Usreg Sri Handajani, .- and Masfah Raudlotus Shofiyyah, .- and Sabrina Aulia Rakhma, .- and Herwin Predianto, .- (2019) Imprinted Zeolite Modified Carbon Paste Electrode as A Selective Potentiometric Sensor for Blood Glucose. In: The 14th Joint Conference on Chemistry 2019. AIP Publishing, Surakarta, Indonesia, 020011-1. ISBN ISSN:0094-243X E-ISSN:1551-7616,

[img] Text (Fulltext)
C27. Fulltext.pdf

Download (2MB)
[img] Text (Penilaian dan Validasi)
C27. Penilaian dan Validasi.pdf

Download (922kB)
[img] Text (Similarity)
C27. Similarity.pdf

Download (2MB)
[img] Text (Bukti Korespondensi)
C27. Bukti Korespondensi_rev.pdf

Download (2MB)
Official URL: https://pubs.aip.org/aip/acp/article-abstract/2237...

Abstract

Imprinted zeolite modified carbon paste electrode as a potentiometric sensor for glucose analysis in blood serum sample has been developed. In this study, the type of used zeolite was TS-1. Imprinted zeolite (IZ) was synthesized with mole ratio of glucose/Si of 0.0306. The modified electrode prepared by mixing activated carbon, imprinted zeolite, and paraffin granule with mass ratio 9:4:7 from the measurement in range of 10−5 – 10−2 M is with Nernst factor of 28.6 mV/decade, and the detection limit of 4.79 x 10-5 M. The electrode was able to respond the glucose molecules in solution quickly (<30 s), stable for more than 9 weeks (130 times usage) and selective to glucose molecules. The urea, uric acid, and creatine with various concentrations did not interfere to glucose analysis by potentiometry using the electrode. Applying of the electrode for glucose analysis in spiked blood serum samples showed that it had recovery of 91.73±3.48% (n=5), while its accuracy against spectrophotometry method as commonly used method in medical field was 90.58±4.65% (n=5). Based on its performance, potentiometry using the imprinted zeolite modified carbon paste electrode is recommended as an alternative method for routine blood glucose analysis in the medical field.

Item Type: Book Section
Subjects: Q Science
Q Science > Q Science (General)
Q Science > QD Chemistry
Q Science > QD Chemistry > QD71-142 Analytical chemistry
Divisions: 08. Fakultas Sains dan Teknologi > Kimia
Creators:
CreatorsNIM
Miratul Khasanah, .-UNSPECIFIED
Alfa Akustia Widati, .-UNSPECIFIED
Usreg Sri Handajani, .-UNSPECIFIED
Masfah Raudlotus Shofiyyah, .-UNSPECIFIED
Sabrina Aulia Rakhma, .-UNSPECIFIED
Herwin Predianto, .-UNSPECIFIED
Depositing User: Mr Vega Andi Budiman
Date Deposited: 03 Jun 2023 07:15
Last Modified: 05 Jun 2023 01:12
URI: http://repository.unair.ac.id/id/eprint/125998
Sosial Share:

Actions (login required)

View Item View Item