An evaluation of phototherapy device performance in a tertiary health facility.

Mahendra T A Sampurna, - and Risa Etika, - and Martono Tri Utomo, Martono and Siti A D Rani, - and Abyan Irzaldy, - and Zahra S Irawan, - and Kinanti Ayu Ratnasari, - and Arend F Bos, - An evaluation of phototherapy device performance in a tertiary health facility. Heliyon 6. ISSN 2405-8440

[img] Text (Kualitas Karil & Kesesuaian Bidang Ilmu)
16. An evaluation of phototherapy device performance in a tertiary health facility.pdf

Download (64kB)
[img] Text (Artikel)
16 text journal an evaluation of phototherapy.pdf

Download (585kB)
[img] Text (Turnitin)
16 turnitin 7% an evaluation of phototherapy.pdf

Download (1MB)
[img] Text (Laik Etik)
4. etik.pdf

Download (139kB)
Official URL: https://pubmed.ncbi.nlm.nih.gov/32995629/

Abstract

Abstract Introduction: A range of phototherapy devices are commercially available. The American Academy of Pediatrics (2004) recommends routine intensity measurement of phototherapy devices to ensure that babies affected by hyperbilirubinemia receive effective phototherapy. Objective: The aims of this study were to calculate the irradiance decay velocity of phototherapy devices used in a tertiary care hospital to evaluate whether current maintenance procedures for phototherapy devices are effective, and to contribute to the improvement of a standardized maintenance procedure in daily practice, thus helping to ensure that all babies affected by hyperbilirubinemia receive prompt treatment. Methods: This research represents a prospective observational study conducted at Dr. Soetomo Academic Teaching Hospital in Surabaya, Indonesia from February 2019-July 2019. The intensities of 11 phototherapy devices were measured at specific times using a Bili Blanket Meter II. We calculated the Δ irradiance differences in μW/cm2/nm and calculated them as velocity μW/cm2/nm/hour of use. Results: Among the 11 phototherapy devices included in this study, nine were fluorescent and two were light-emitting diode (LED) machines. The mean (standard deviation) irradiance decay velocity of the fluorescent lamps was 0.02 (±0.03) μW/cm2/nm/hour of use, while that of the LED lamps was 0.015 (±0.007) μW/cm2/nm/hour of use. The fastest irradiance decay velocity was 0.08 μW/cm2/nm/hour of use, while the slowest irradiance decay velocity was <0.01 μW/cm2/nm/hour of use, both of which were from fluorescent-based devices. There was one fluorescent-based device that provided an intensity lower than the therapeutic level. Conclusion: Irradiance decay occurred in all phototherapy device lamps. It is important to perform routinely intensity measurements, regardless of manufacturer recommendations, to avoid ineffective phototherapy resulting from intensities lower than the required therapeutic levels.

Item Type: Article
Subjects: R Medicine > R Medicine (General) > R5-920 Medicine (General)
Divisions: 01. Fakultas Kedokteran > Ilmu Kesehatan Anak (Sub Spesialis)
Creators:
CreatorsNIM
Mahendra T A Sampurna, -UNSPECIFIED
Risa Etika, -UNSPECIFIED
Martono Tri Utomo, MartonoNIDN0026017304
Siti A D Rani, -UNSPECIFIED
Abyan Irzaldy, -UNSPECIFIED
Zahra S Irawan, -UNSPECIFIED
Kinanti Ayu Ratnasari, -UNSPECIFIED
Arend F Bos, -UNSPECIFIED
Depositing User: arys fk
Date Deposited: 08 May 2023 00:56
Last Modified: 07 Aug 2023 00:17
URI: http://repository.unair.ac.id/id/eprint/126308
Sosial Share:

Actions (login required)

View Item View Item