Hydroxyapatite coating on cobalt alloys using electrophoretic deposition method for bone implant application

Aminatun*, .- and N.S Efinda Putri, .- and Arista Indriani, .- and Umi Himawati, .- and Dyah Hikmawati, .- and Suhariningsih, .- Hydroxyapatite coating on cobalt alloys using electrophoretic deposition method for bone implant application. In: International Conference on Physical Instrumentation and Advanced Material. IOP Publishing, Hotel Santika Premiere, Surabaya, Indonesia.

[img] Text (Fulltext)
C15. Fulltext .pdf

Download (801kB)
[img] Text (Penilaian dan Validasi)
C15. Penilaian dan Validasi_.pdf

Download (580kB)
[img] Text (Similarity)
C15. Simillarity.pdf

Download (2MB)
Official URL: https://iopscience.iop.org/article/10.1088/1742-65...

Abstract

Damage on bone due to osteoporosis and cancer triggered high demand for bone implant prosthesis which is a permanent implant. Thus, a prosthesis coated with hydroxyapatite (HA) is required because it is osteoconductive that can trigger the growth of osteoblast cells. The purpose of this study is to determine the optimum concentration of HA suspension in terms of the surface morphology, coating thickness, adhesion strength and corrosion rate resulting in the HA coating with the best characteristics for bone implant. Coating using electrophoretic deposition (EPD) method with concentrations of 0.02M, 0.04M, 0.06M, 0.08M, and 0.1M was performed on the voltage and time of 120V and 30 minutes respectively. The process was followed by sintering at the temperature of 900 °C for 10 minutes. The results showed that the concentration of HA suspension influences the thickness and the adhesion of layer of HA. The higher the concentration of HA-ethanol suspension the thicker the layer of HA, but its coating adhesion strength values became lower. The concentration of HA suspension of 0.04 M is the best concentration, with characteristics that meet the standards of the bone implant prosthesis. The characteristics are HA coating thickness of 199.93 ± 4.85 μm, the corrosion rate of 0.0018 mmpy and adhesion strength of 4.175 ± 0.716 MPa.

Item Type: Book Section
Subjects: Q Science
Q Science > Q Science (General)
Q Science > QC Physics
Q Science > QC Physics > QC1 Physics (General)
Divisions: 08. Fakultas Sains dan Teknologi > Tekno Biomedik
Creators:
CreatorsNIM
Aminatun*, .-UNSPECIFIED
N.S Efinda Putri, .-UNSPECIFIED
Arista Indriani, .-UNSPECIFIED
Umi Himawati, .-UNSPECIFIED
Dyah Hikmawati, .-UNSPECIFIED
Suhariningsih, .-UNSPECIFIED
Depositing User: Mr Vega Andi Budiman
Date Deposited: 23 Jun 2023 10:21
Last Modified: 23 Jun 2023 10:21
URI: http://repository.unair.ac.id/id/eprint/127563
Sosial Share:

Actions (login required)

View Item View Item