Six Sigma for Performance Analysis of Quality Control in Laboratory

Laily hidayati, - and Muhamad Robi'ul Fuadi, - (2018) Six Sigma for Performance Analysis of Quality Control in Laboratory. Six Sigma for Performance Analysis of Quality Control in Laboratory, 6 (5). pp. 507-510. ISSN 2321-9637

[img] Text (Jurnal)
Six Sigma for Performance Analysis of Quality Control in Laboratory.pdf

Download (160kB)
[img] Text (Karil)
K-Six Sigma for Performance Analysis of Quality Control in Laboratory.pdf

Download (251kB)
[img] Text (Turnitin)
Six Sigma for Performance Analysis of Quality Control in Laboratory.pdf.pdf

Download (1MB)
Official URL: https://ijrat.org/downloads/Vol-6/may-2018/paper%2...

Abstract

The accuracy and thoroughness of the results of laboratory tests is very important for patients and doctors because ± 70% of medical measures to be performed are based on the results of laboratory tests. Six sigma is one method that can be used to assess the quality of laboratory examination results. The purpose of this research is to analyze the clinical chemistry parameter performance by using sigma and to arrange control strategy plan at clinical chemicals cobas C 311 in Clinical Pathology Laboratory of Airlangga Hospital. This research is a retrospective observational study. Primary data were obtained from internal quality control documents in January and February 2018. The control materials used were precicontrol clin-chem multi 1 which was done using the Cobas C311 tool. The parameters were evaluated by SGOT, SGPT, ALB, BUN, CREAT, UA, GLU, CHOL, TRIG, HDL and LDL. The results of the examination were calculated of imprecise value (CV) inoculation (Bias) and sigma value. The highest Bias value is HDL and the lowest is CHOL. The highest CV value is UREUM and the lowest is LDL. The average sigma value of the parameter examined is 4-6 sigma (good to excellent performance). The highest sigma value is in the parameter SGOT, SGPT, HDL and LDL. They have sigma value > 6 (world class performance). The lowest sigma value is performing at UREUM obtained one sigma value (poor performance).The mean of sigma value at parameter which assessed is 4-6 sigma (good to excellent performance) ALB, CREAT, UA, GLU, CHOL and TRIG its meaning that the clinical chemistry is suitable for routine examination. Parameters that have poor performance should be fixed.

Item Type: Article
Subjects: L Education
Divisions: 01. Fakultas Kedokteran > Patologi Klinik