OPTIMASI DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS HIDROKUINON DALAM KRIM

MUHAMAD HIDAYATULLAH CHOIR, 051211133052 (2016) OPTIMASI DAN VALIDASI METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS HIDROKUINON DALAM KRIM. Skripsi thesis, Universitas Airlangga.

[img]
Preview
Text (abstrak)
FF. KF. 09-16 Cho o abstrak.pdf

Download (561kB) | Preview
[img] Text (fulltext)
FF. KF. 09-16 Cho o.pdf
Restricted to Registered users only

Download (2MB) | Request a copy
Official URL: http://lib.unair.ac.id

Abstract

OPTIMIZATION AND VALIDATION OF HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR THE ANALYSIS HYDROQUINONE IN CREAM Hydroquinone (HQ) is used for threatment of hyperpigmented condition and also one of the active ingredients used in cosmetics. The objective of the present study was to optimize and validate the high performance liquid chromatography method for the analysis of a hidrqoquinone in cream. Chromatographic separation was achieved on Microbundapak C18 (3.9 x 300) 10 μm 125 A column and the mobile phase was a mixture methanol : water (40 : 60). The retention time for hydroquinone was 3.92 min, at flow rate of 0.8 mL/min. The UV detector was set 289 nm. The method was validated for specificity, linearity, accuracy, precision, limits of detection, and limits of quantification. The method was proved to be selective. Linearity showed linear respone (r = 0.9998) while correlation coeffecient of the function (Vxo) was 0.98% over the range of concentration used (between 5 mg L-1 to 35 mg L-1). Accuracy of method was in range of accepted limits (97% - 103%), recovery was found to be in the average of 101.78%, while the precision was 1.25%. The detection limit is 0.06 ppm and the quantification limit is 0.18 ppm. The proposed method was successfully applied for the analysis of hydroquinone in cream Keyword : OPTIMIZATION AND VALIDATION OF HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR THE ANALYSIS HYDROQUINONE IN CREAM Hydroquinone (HQ) is used for threatment of hyperpigmented condition and also one of the active ingredients used in cosmetics. The objective of the present study was to optimize and validate the high performance liquid chromatography method for the analysis of a hidrqoquinone in cream. Chromatographic separation was achieved on Microbundapak C18 (3.9 x 300) 10 μm 125 A column and the mobile phase was a mixture methanol : water (40 : 60). The retention time for hydroquinone was 3.92 min, at flow rate of 0.8 mL/min. The UV detector was set 289 nm. The method was validated for specificity, linearity, accuracy, precision, limits of detection, and limits of quantification. The method was proved to be selective. Linearity showed linear respone (r = 0.9998) while correlation coeffecient of the function (Vxo) was 0.98% over the range of concentration used (between 5 mg L-1 to 35 mg L-1). Accuracy of method was in range of accepted limits (97% - 103%), recovery was found to be in the average of 101.78%, while the precision was 1.25%. The detection limit is 0.06 ppm and the quantification limit is 0.18 ppm. The proposed method was successfully applied for the analysis of hydroquinone in cream Keyword : HPLC, Hydroquinone, Validation Method

Item Type: Thesis (Skripsi)
Additional Information: KKB KK-2 FF. KF. 09-16 Cho o
Uncontrolled Keywords: HPLC, Hydroquinone, Validation Method
Subjects: R Medicine > RS Pharmacy and materia medica > RS200-201 Pharmaceutical dosage forms
Divisions: 05. Fakultas Farmasi > Kimia Farmasi
Creators:
CreatorsNIM
MUHAMAD HIDAYATULLAH CHOIR, 051211133052UNSPECIFIED
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorSugijanto, Prof. Dr., MS.,AptUNSPECIFIED
Thesis advisorAmirudin Prawita, Prof. Dr. H., AptUNSPECIFIED
Depositing User: Tatik Poedjijarti
Date Deposited: 06 Apr 2017 18:59
Last Modified: 06 Apr 2017 18:59
URI: http://repository.unair.ac.id/id/eprint/56100
Sosial Share:

Actions (login required)

View Item View Item