ACUTE EFFECT OF VAPING ON OXYGEN SATURATION LEVEL, BLOOD PRESSURE AND PULSE RATE

Diar Pasahari, NIM011511133225 INTERNATIONAL (2018) ACUTE EFFECT OF VAPING ON OXYGEN SATURATION LEVEL, BLOOD PRESSURE AND PULSE RATE. Skripsi thesis, Universitas Airlangga.

[img] Text (abstrak)
abstrak.pdf

Download (121kB)
[img] Text (fulltext)
fulltext.pdf
Restricted to Registered users only until 29 January 2022.

Download (2MB) | Request a copy
Official URL: http://lib.unair.ac.id

Abstract

developed a substitution for traditional cigarettes, an electronic alternative cigarettes called Vaporizer, first entered the U.S market in 2007. Vaping are becoming an alternative choice for many smoker because of their ppearance , sense , and flavor compared to traditional cigarettes. Both of e-cigarette and conventional cigarette delivers nicotine aside from nicotine , propylene glycol and glycerin are the basic ingredients of the solution that vaporizer device use to make the aerosol. There was also increasing of vape user among the students in Airlangga University Faculty of Medicine, and it was increasing by time, and that is one of the reason, why this research is arranged. The type of design used in this research is quasi experimental where every subject will be their own control. Observation of the result variable will be done before and after the treatment. The population and sample of this research are from medical students of Airlangga University Faculty of Medicine, where the subject is a vape user. Total sampling was used to determine the amount of the sample . This research is using pulse oximetry as the tool to measure the oxygen saturation level (SpO2). Oxygen aturation will be measured before and after the subject vape for a short time. Extra data is also observed including pulse rate and blood pressure. Pulse rate was measured also using pulse oximetry, while the blood pressure was measured using mechanical sphygmomanometer. The data then analysed using SPSS and presented in tables. This research found that there was a decrease on SpO2 level after vaping in a short time, after statistically analysed with the p value 0.019 meaning that there was a significant change. While in medical view small change of value does not always give a meaningful effect. And there was also an increase of pulse rate and blood pressure, the p value for pulse rate is 0.042 meaning that there was a significant change. For the blood pressure there was significant change for the systolic pressure with the p value 0.001, while there was no change in the diastolic pressure with the p value 0.108. This esearch conclude that , vaping in a short time could give acute effect on SpO2 level and also on pulse rate and blood pressure. It have possibility to give an adverse effect to health, though not always a significant change by tatistical result have a meaningful interpretation in medical point of view. Further research regarding vape need to be established for a better understanding.

Item Type: Thesis (Skripsi)
Additional Information: KKA KK FK.PD 11/19 Pas a
Uncontrolled Keywords: E-cigarette, vape, acute effect of vaping, oxygen saturation, nicotine
Subjects: R Medicine > RC Internal medicine > RC705-779 Diseases of the respiratory system
Divisions: 01. Fakultas Kedokteran > Pendidikan Dokter
Creators:
CreatorsNIM
Diar Pasahari, NIM011511133225 INTERNATIONALNIM011511133225 INTERNATIONAL
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorNancy Margarita Rehatta, Prof., Dr. , dr., Sp.AnK.IC., KNA., KMN.)UNSPECIFIED
Thesis advisorBambang Purwanto, Dr. dr., M.kes.UNSPECIFIED
Depositing User: Ny Wahyuni -
Date Deposited: 29 Jan 2019 08:16
Last Modified: 30 Jan 2019 01:17
URI: http://repository.unair.ac.id/id/eprint/79672
Sosial Share:

Actions (login required)

View Item View Item