Selective Identification for Glucose in the Presence of Fructose Using Imprinted Polyeugenol Modified Graphite Paste Electrode

Muhammad Cholid Djunaidi, .- and Gunawan Gunawan,, .- and Lutfia Cahyaningrum, .- and Retno Ariadi Lusiana, .- and Miratul Khasanah, .- (2022) Selective Identification for Glucose in the Presence of Fructose Using Imprinted Polyeugenol Modified Graphite Paste Electrode. Indonesian Journal of Chemistry, 22 (4). pp. 913-921. ISSN p-ISSN: 14119420; e-ISSN: 24601578

[img] Text (Fulltext)
C17. Fulltext.pdf

Download (6MB)
[img] Text (Penilaian dan Validasi)
C17. Penilaian dan Validasi.pdf

Download (973kB)
[img] Text (Similarity)
C17. Similarity.pdf

Download (2MB)
Official URL: https://journal.ugm.ac.id/ijc/article/view/71013

Abstract

High blood glucose levels indicate diabetes mellitus. The conventional way was carried out to determine glucose levels, but this method just shows the total reducing sugar levels. An electrode was developed to analyze glucose in the presence of fructose by potentiometry. The optimum graphite paste electrodes-Imprinted based on polyeugenol and Ethylene Glycol Dimethacrylate (EGDMA) as crosslinkers, had been used as a glucose sensor. Polyeugenol was made by the polymerization reaction with a BF3 catalyst with a molecular weight of 6451.338 g/mol. A total of 2135.99 glucose was contacted with polyeugenol, and the result was crosslinked with EGDMA and 2,2'-Azobis(2-methylpropionitrile) (AIBN) initiator, then Molecularly Imprinted Polymer (MIP) was generated. The optimization of electrodes showed that the best composition of MIP: paraffin: graphite is 20:35:45 with the 19.16 mV/decade Nernstian Factor, which can measure samples at the range 10–5–10–1 M with a detection limit of 1.0334 × 10–5 M, a response time of 6–15 s, a lifetime (use) of 19 times and has good selectivity on fructose sample with Kij less than 1. Measurements using this electrode showed that honey contains 28.78% of glucose, not much different from the UV-Vis spectrophotometry, which is 29.68%, and HPLC is 30.42%.

Item Type: Article
Uncontrolled Keywords: polyeugenol; imprinted; glucose; fructose; selective electrode
Subjects: Q Science
Q Science > Q Science (General)
Q Science > QD Chemistry
Divisions: 08. Fakultas Sains dan Teknologi > Kimia
Creators:
CreatorsNIM
Muhammad Cholid Djunaidi, .-UNSPECIFIED
Gunawan Gunawan,, .-UNSPECIFIED
Lutfia Cahyaningrum, .-UNSPECIFIED
Retno Ariadi Lusiana, .-UNSPECIFIED
Miratul Khasanah, .-NIDN0004036705
Depositing User: Mr Vega Andi Budiman
Date Deposited: 09 May 2023 00:50
Last Modified: 03 Jun 2023 07:08
URI: http://repository.unair.ac.id/id/eprint/125988
Sosial Share:

Actions (login required)

View Item View Item