Validation Of Uv-Visibles Pectrophotometric Method For The Determination Of Tetracycline Concentration In Shrimp

Muhamad Nizar Ilham Kusuma (2020) Validation Of Uv-Visibles Pectrophotometric Method For The Determination Of Tetracycline Concentration In Shrimp. Skripsi thesis, UNIVERSITAS AIRLANGGA.

[img] Text (HALAMAN JUDUL)
1.COVER.pdf

Download (557kB)
[img] Text (ABSTRAK)
2.ABTRACT.pdf

Download (124kB)
[img] Text (DAFTAR ISI)
3.TABLE OF CONTENT.pdf

Download (136kB)
[img] Text (BAB I)
4.CHAPTER 1 .pdf

Download (112kB)
[img] Text (BAB II)
5.CHAPTER 2 .pdf
Restricted to Registered users only until 8 December 2023.

Download (274kB) | Request a copy
[img] Text (BAB III)
6.CHAPTER 3 .pdf
Restricted to Registered users only until 8 December 2023.

Download (145kB) | Request a copy
[img] Text (BAB IV)
7.CHAPTER 4 .pdf
Restricted to Registered users only until 8 December 2023.

Download (314kB) | Request a copy
[img] Text (BAB V)
8.CHAPTER 5 .pdf
Restricted to Registered users only until 8 December 2023.

Download (110kB) | Request a copy
[img] Text (BAB VI)
9.CHAPTER 6 .pdf
Restricted to Registered users only until 8 December 2023.

Download (100kB) | Request a copy
[img] Text (DAFTAR PUSTAKA)
10.REFERENCES.pdf

Download (117kB)
[img] Text (LAMPIRAN)
11.APPENDIX.pdf
Restricted to Registered users only until 8 December 2023.

Download (148kB) | Request a copy
[img] Text
135-Kesediaan - muhamad nizar.pdf
Restricted to Registered users only

Download (219kB) | Request a copy
Official URL: http://www.lib.unair.ac.id

Abstract

The use of Tetracycline to treat bacterial diseases in aquaculture with excessive amounts has the potential to encourage the emergence of antibiotic-resistant bacteria. The purpose of this study is to ensure that this method can be used as an option to determine the concentration of Tetracycline in shrimp. UV-Visible spectrophotometer instruments are used to measure the absorption of electromagnetic radiation at several Tetracycline concentrations. The optimal wavelength obtained for Tetracycline analysis was 273 nm. The parameters of the validation methods used in this study are selectivity, linearity, precision, accuracy, the limit of detection, and limit of quantitation. The proposed method showed good selectivity that the maximum absorption of Tetracycline was not affected by the absorption of other compounds contained in the sample. Linearity test with a range of analytes concentrations of 0.375 ppm to 3.75 ppm produced r = 0.9982. The accuracy (%recovery) of Tetracycline was 111.52%, while the precision (CV) was less than 16%. The limit of detection value was 0,288 ppm, and the limit of quantitation value was 0,96 ppm.

Item Type: Thesis (Skripsi)
Additional Information: KKC KK KH.135-20 Kus v
Uncontrolled Keywords: Tetracycline, UV-Visible Spectrophotometer, Method validation, Shrimp
Subjects: Q Science
Q Science > QD Chemistry > QD415-436 Biochemistry
Q Science > QP Physiology > QP501-801 Animal biochemistry
Divisions: 06. Fakultas Kedokteran Hewan
Creators:
CreatorsNIM
Muhamad Nizar Ilham KusumaNIM061611133140
Contributors:
ContributionNameNIDN / NIDK
Thesis advisorBoedi Setiawan, -NIDN0016037103
Thesis advisorMochamad LazuardiNIDN0018125804
Depositing User: hardiansah pramana abdilah
Date Deposited: 30 Dec 2020 13:45
Last Modified: 30 Dec 2020 13:45
URI: http://repository.unair.ac.id/id/eprint/101374
Sosial Share:

Actions (login required)

View Item View Item