Diagnostic Accuracy of Recto-Sigmoid Index Evaluation on Barium Enema in Hirchsprung’s Disease

Emma Ratna Fury, - and Alpha Fardah Athiyah, - and Andy Darma, - (2021) Diagnostic Accuracy of Recto-Sigmoid Index Evaluation on Barium Enema in Hirchsprung’s Disease. Indian Journal of Forensic Medicine & Toxicology, 15 (1). pp. 1045-1051. ISSN 09739122

[img] Text (Artikel)
12. Diagnostic Accuracy of Recto-Sigmoid Index Evaluation on Barium Enema in Hirchsprung’s Disease.pdf

Download (824kB)
[img] Text (Similarity)
12. Diagnostic Accuracy of Recto-Sigmoid Index Evaluation on Barium Enema in Hirchsprung’s Disease.pdf

Download (1MB)
[img] Text (Peer Review)
Diagnostic Accuracy.pdf

Download (1MB)
Official URL: https://medicopublication.com/index.php/ijfmt/arti...

Abstract

Background: Hirschsprung’s disease is a congenital disease caused by the absence of ganglion cells in the bowel wall, which results in functional obstruction of the aganglionic segment due to failure of relaxation during peristalsis. The recto-sigmoid index on barium enema may constitute in the diagnosis of Hirschsprung’s disease. Aim: To evaluate the sensitivity, specificity, positive predictive value, and negative predictive value of recto-sigmoid index for the diagnosis of Hirschsprung’s disease in patients who underwent barium enema examination. Methods: This retrospective study was conducted in Dr Soetomo Hospital. Medical records of patients suspected of Hirscsprung’s disease who underwent both barium enema examination and diagnostic full thickness biopsy were evaluated. Moreover, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of recto-sigmoid index was calculated. Results: A total of 37 patients were examined; 21 of them were male. The average age was 24.5 (SD 17.34, range 1 month-72 month). Biopsy revealed the absence of ganglion cells in 32 (91,8%) patients. The rectosigmoid index agreed with the histopathologic diagnosis in 30 (81%.) patients. The sensitivity, specificity, PPV, and NPV were 87.5%, 40%, 90.5% and 33% respectively. Conclusion: Recto-sigmoid index evaluation in barium enema for the diagnosis of Hirscsprung’s disease has poor diagnostic accuracy.

Item Type: Article
Uncontrolled Keywords: Hirschsprung’s disease, aganglionic, recto-sigmoid index, barium enema
Subjects: R Medicine > R Medicine (General)
R Medicine > RJ Pediatrics
Divisions: 01. Fakultas Kedokteran > Ilmu Kesehatan Anak (Sub Spesialis)
Creators:
CreatorsNIM
Emma Ratna Fury, -UNSPECIFIED
Alpha Fardah Athiyah, -NIDN0023087301
Andy Darma, -UNSPECIFIED
Depositing User: arys fk
Date Deposited: 27 Oct 2021 08:56
Last Modified: 27 Oct 2021 08:56
URI: http://repository.unair.ac.id/id/eprint/107350
Sosial Share:

Actions (login required)

View Item View Item