Choosing between the Conventional Plates, Locking Plates, or Iliosacral Screws for Sacroiliac Joint Dislocation: A Biomechanic Comparative Study

Trixie Brevi Putri, Trixie and Erwin Ramawan, Erwin and Mohammad Zaim Chilmi, Mohammad and Kukuh Dwiputra Hernugrahanto, Kukuh and Jifaldi Afrian Maharaja Dinda Sedar, Jifaldi and Fundhy Sinar Ikrar Prihatanto, Fundhy Choosing between the Conventional Plates, Locking Plates, or Iliosacral Screws for Sacroiliac Joint Dislocation: A Biomechanic Comparative Study. The Hip and Knee Journal, 2 (1). pp. 28-33. ISSN 2723-7826

[img] Text (Artikel)
C-13 Artikel.pdf

Download (744kB)
[img] Text (Kualitas Karil & Kesesuaian Bidang Ilmu)
C-13 Karil.pdf

Download (178kB)
[img] Text (Laik Etik)
C-13 Etik.pdf

Download (961kB)
[img] Text (Turnitin)
C-13 Turnitin.pdf

Download (2MB)
Official URL: https://thehipkneejournal.id/index.php/hipknee/art...

Abstract

Abstract Background: This study examines the comparison of biomechanical strengths of three kinds of the most familiar implants available in Indonesia: conventional and locking sacroiliac plates and screws, also iliosacral screws. Despite the common thought that iliosacral screws are preferred compared to conventional plates and screws due to its biomechanic superiority, this study tested whether the locking plates and screws could offer an alternative. Materials and Methods: This study was an in vitro experimental study with a Randomized Post Test - Only Control Group Design using pelvic bones from male cadavers aged 20-50 y.o. Twelve samples were divided into three treatment groups and one control group. Group P1 was fixed with two conventional plates, P2 was fixed with two locking plates, P3 was fixed with two iliosacral screws, and control group K with sacroiliac joint was intact. Each group was given an increasing load until a vertical shift of the sacroiliac joint ≥ 2.0 mm was obtained. Results: The average force load for 2 mm displacement among the fixation systems being tested shows a statistically significant difference (p<0.05). Load failure force for 2 mm displacement in the locking plate and screw group has the highest average (591.33 ± 56.08 N) compared to the iliosacral screw group (583.67 ± 73.56 N) and conventional plate and screw group (574 ± 106.05 N). Conclusions: Biomechanically, the fixation system using two locking anterior sacroiliac plates and screws is more stable than the iliosacral screws and conventional sacroiliac plates and screws.

Item Type: Article
Subjects: R Medicine
R Medicine > R Medicine (General) > R5-920 Medicine (General)
Divisions: 01. Fakultas Kedokteran > Orthopaedi dan Traumatologi
Creators:
CreatorsNIM
Trixie Brevi Putri, TrixieUNSPECIFIED
Erwin Ramawan, ErwinUNSPECIFIED
Mohammad Zaim Chilmi, MohammadNIDN8887130017
Kukuh Dwiputra Hernugrahanto, KukuhNIM011228126302
Jifaldi Afrian Maharaja Dinda Sedar, JifaldiUNSPECIFIED
Fundhy Sinar Ikrar Prihatanto, FundhyUNSPECIFIED
Depositing User: arys fk
Date Deposited: 28 Apr 2023 08:28
Last Modified: 28 Apr 2023 08:28
URI: http://repository.unair.ac.id/id/eprint/125512
Sosial Share:

Actions (login required)

View Item View Item